ExpiredGoodsAmended (1x)

Aethalometer- Supply Arrangement (SA) E60PV-19EQUI

Arrangements en matière d’approvisionnement pour les Aethalomètres (AA) E60PV-19EQUI

Description

Environment and Climate Change Canada has a requirement for an aethalometer to measure BC and BrC absorption for laboratory and field studies. Mandatory Technical Criteria: The following requirements are the mandatory technical evaluation criteria which will be evaluated during the Bid Evaluation. In addition, the Contractor will be required to meet all of the mandatory technical requirements for the duration of the Contract. Bidders are requested to cross reference the mandatory technical criteria in a concise format by using page, paragraph(s) & sub-paragraphs as applicable to their supporting technical documentation. Item Criteria Reference to substantiation in the Technical Bid M1 Must include a field deployable aethalometer to measure aerosol absorption at multiple wavelengths (from the ultraviolet to the near-infrared) simultaneously. M2 Must be able to provide continuous data for eliminating the filter loading effect M3 Must include an inlet cyclone/impactor for measuring aerosol absorption in PM1 and PM2.5 M4 Must include a dryer with a pump for continuously conditioning the sample flow M5 Must include a calibration kit to validate the optical performance of the instrument M6 Must have USB ports, digital data ports, and Ethernet for data transfer M7 Must be able to measure aerosol absorption at 9 different wavelengths or more between 340 nm and 950 nm simultaneously. M8 Must be able to measure aerosol absorption at 3 different wavelengths or more between 340 nm and 450 nm simultaneously for BrC characterization M9 Must be able to provide aerosol absorption measurement at 5 years of 1-minute resolution data.

Quick Summary

Environment and Climate Change Canada is seeking to establish a supply arrangement for an aethalometer used to measure black carbon and brown carbon absorption in both laboratory and field studies. The equipment must be field deployable and capable of continuous data collection with specific features like aerosol size selection and sample conditioning. The contracting entity is the Department of the Environment (ECCC) in Quebec.

Ideal For

Companies specializing in advanced environmental monitoring instruments and scientific measurement devices should consider bidding.

Environmental Monitoring EquipmentAir Quality MeasurementScientific InstrumentsLaboratory EquipmentField Research Equipment
High complexity

Tender Details

Reference Number
cb-923-73140898
Solicitation Number
5000088813
Publication Date
Sep 16, 2025
Closing Date
Sep 30, 2025
Expected Start
Dec 1, 2025
Expected End
Mar 31, 2026
Procurement Method
Competitive - Selective tendering
Selection Criteria
Lowest Price
Notice Type
RFP against Supply Arrangement

Classification

UNSPSC Code
41100000
UNSPSC Description
Laboratory and scientific equipment

Trade Agreements

Please refer to Tender Description or Tender Documents

Contracting Entity

Department of the Environment (ECCC )

351, boul. Saint-Joseph,

Gatineau, Quebec

Contact

Mitchell Palmer

mitchell.palmer@ec.gc.ca

873499-5126

Regions of Delivery

Canada